Manpage logo

cxl-set-alert-config - set the warning alert threshold on a CXL memdev

NAME  SYNOPSIS  DESCRIPTION  EXAMPLES  OPTIONS  SEE ALSO 

NAME

cxl-set-alert-config − set the warning alert threshold on a CXL memdev

SYNOPSIS

cxl set−alert−config <mem0> [<mem1>..<memN>] [<options>]

DESCRIPTION

CXL device raises an alert when its health status is changed. Critical alert shall automatically be configured by the device after a device reset. If supported, programmable warning thresholds also be initialized to vendor recommended defaults, then could be configured by the user.

Use this command to configure warning alert thresholds of a device. Having issued this command, the newly requested warning thresholds would override the previously programmed warning thresholds.

To enable warning alert, set both threshold=value and alert=on. To disable warning alert, set only alert=off. Other cases would cause errors.

Use "cxl list −m <memdev> −A" to examine the programming warning threshold capabilities of a device.

EXAMPLES

Set warning threshold to 30 and enable alert for life used.

# cxl set−alert−config mem0 −−life−used−threshold=30 −−life−used−alert=on
{
  "memdev":"mem0",
  "ram_size":"1024.00 MiB (1073.74 MB)",
  "alert_config":{
    "life_used_prog_warn_threshold_valid":true,
    "dev_over_temperature_prog_warn_threshold_valid":false,
    "dev_under_temperature_prog_warn_threshold_valid":false,
    "corrected_volatile_mem_err_prog_warn_threshold_valid":false,
    "corrected_pmem_err_prog_warn_threshold_valid":false,
    "life_used_prog_warn_threshold_writable":true,
    "dev_over_temperature_prog_warn_threshold_writable":true,
    "dev_under_temperature_prog_warn_threshold_writable":true,
    "corrected_volatile_mem_err_prog_warn_threshold_writable":true,
    "corrected_pmem_err_prog_warn_threshold_writable":true,
    "life_used_crit_alert_threshold":75,
    "life_used_prog_warn_threshold":30,
    "dev_over_temperature_crit_alert_threshold":0,
    "dev_under_temperature_crit_alert_threshold":0,
    "dev_over_temperature_prog_warn_threshold":0,
    "dev_under_temperature_prog_warn_threshold":0,
    "corrected_volatile_mem_err_prog_warn_threshold":0,
    "corrected_pmem_err_prog_warn_threshold":0
  },
  "serial":"0",
  "host":"0000:0d:00.0"
}
cxl memdev: cmd_set_alert_config: set alert configuration 1 mem

Disable warning alert for life_used.

# cxl set−alert−config mem0 −−life−used−alert=off
{
  "memdev":"mem0",
  "ram_size":"1024.00 MiB (1073.74 MB)",
  "alert_config":{
    "life_used_prog_warn_threshold_valid":false,
    "dev_over_temperature_prog_warn_threshold_valid":false,
    "dev_under_temperature_prog_warn_threshold_valid":false,
    "corrected_volatile_mem_err_prog_warn_threshold_valid":false,
    "corrected_pmem_err_prog_warn_threshold_valid":false,
    "life_used_prog_warn_threshold_writable":true,
    "dev_over_temperature_prog_warn_threshold_writable":true,
    "dev_under_temperature_prog_warn_threshold_writable":true,
    "corrected_volatile_mem_err_prog_warn_threshold_writable":true,
    "corrected_pmem_err_prog_warn_threshold_writable":true,
    "life_used_crit_alert_threshold":75,
    "life_used_prog_warn_threshold":30,
    "dev_over_temperature_crit_alert_threshold":0,
    "dev_under_temperature_crit_alert_threshold":0,
    "dev_over_temperature_prog_warn_threshold":0,
    "dev_under_temperature_prog_warn_threshold":0,
    "corrected_volatile_mem_err_prog_warn_threshold":0,
    "corrected_pmem_err_prog_warn_threshold":0
  },
  "serial":"0",
  "host":"0000:0d:00.0"
}
cxl memdev: cmd_set_alert_config: set alert configuration 1 mem

OPTIONS

<memory device(s)>

A memX device name, or a memdev id number. Restrict the operation to the specified memdev(s). The keyword all can be specified to indicate the lack of any restriction.

−S, −−serial

Rather an a memdev id number, interpret the <memdev> argument(s) as a list of serial numbers.

−L, −−life−used−threshold=

Set <value> for the life used warning alert threshold.

−−life−used−alert=

Enable or disable the life used warning alert. Options are on or off.

−O, −−over−temperature−threshold=

Set <value> for the device over temperature warning alert threshold.

−−over−temperature−alert=

Enable or disable the device over temperature warning alert. Options are on or off.

−U, −−under−temperature−threshold=

Set <value> for the device under temperature warning alert threshold.

−−under−temperature−alert=

Enable or disable the device under temperature warning alert. Options are on or off.

−V, −−volatile−mem−err−threshold=

Set <value> for the corrected volatile memory error warning alert threshold.

−−volatile−mem−err−alert=

Enable or disable the corrected volatile memory error warning alert. Options are on or off.

−P, −−pmem−err−threshold=

Set <value> for the corrected persistent memory error warning alert threshold.

−−pmem−err−alert=

Enable or disable the corrected persistent memory error warning alert. Options are on or off.

−v, −−verbose

Turn on verbose debug messages in the library (if libcxl was built with logging and debug enabled).

SEE ALSO

CXL−3.0 8.2.9.8.3.3


Updated 2026-06-01 - jenkler.se | uex.se