cec-compliance - An application to verify remote CEC devices

NAME  SYNOPSIS  DESCRIPTION  OPTIONS  EXIT STATUS  EXAMPLE  BUGS  SEE ALSO 

NAME

cec-compliance - An application to verify remote CEC devices

SYNOPSIS

cec-compliance [-h] [-d <dev>] [other options]

DESCRIPTION

The cec-compliance utility can be used to test how well remote CEC devices comply with the CEC specification. It can also be used to test the local CEC adapter (with the -A option).

By default it will run through all tests, but if one or more of the feature test options is given, then only those tests will be performed. A set of core tests is always run.

The CEC adapter needs to be configured before it is used to run tests with cec-compliance. Use cec-ctl for configuration.

If the CEC adapter has claimed several logical addresses, the test set is run from each logical address in succession. The remote device needs to report a valid physical address in order to run tests on it.

When running compliance tests, cec-follower should be run on the same adapter. cec-follower will reply to messages that are not handled by cec-compliance. cec-follower will also monitor the device under test for behaviors that are not compliant with the specification. Before each test-run cec-follower should be restarted if it is already running, to initialize the emulated device with a clean and known initial state.

Some tests require interactive mode (with the -i option) to confirm that the test passed. When in interactive mode, the user is asked to observe or perform actions on the remote device. Some tests also give conclusive test results when run in interactive mode.

When testing the local CEC adapter’s compliance with the CEC API, there must be at least one remote device present in order to test transmitting and receiving.

The compliance tests can have several possible outcomes besides passing and failing:

OK The test passed.

OK (Unexpected) The test passed, but it was unexpected for the device
under test to support it. This might for example occur
when a TV replies to messages in the Deck Control
feature.

OK (Not Supported) The feature that was tested is not supported by the
device under test, and that feature was not mandatory for
the device to pass.

OK (Presumed) Nothing went wrong during the test, but the test cannot
positively verify that the required effects of the test
occurred. The test runner should verify that the test
passed by manually observing the device under test. This
is typically the test result for tests that send
messages that are not replied to, but which induce some
side effect on the device under test, such as a TV
switching to another input or sending a Remote Control
command.

OK (Refused) The device supports the feature or message being tested,
but responded <Feature Abort> ["Refused"] to indicate
that it cannot perform the given operation. This might
for example occur when trying to test the One Touch
Record feature on a TV with copy protection enabled.

FAIL The test failed and was expected to pass on the device.

OK (Expected Failure) Failed but this was expected. This can only happen
if the −−expect option was used that specified
that a particular test would return a FAIL result.

FAIL (Expected X, got Y) The test returned a different result than was expected.
This can only happen if the −−expect option was used
that specified that a particular test would return a specific
non-FAIL result.

Some tests depend on other tests being successful. These are not run if the tests they depend on failed, and they will not be shown in the test listing.

OPTIONS

−d, −−device <dev>

Use device <dev> as the CEC device. If <dev> is a number, then /dev/cec<dev> is used.

−D, −−driver <drv>

Use a cec device that has driver name <drv>, as returned by the CEC_ADAP_G_CAPS ioctl. This option can be combined with −a to uniquely identify a CEC device without having to rely on the device node number.

−a, −−adapter <adap-name>

Use a cec device that has adapter name <adap-name>, as returned by the CEC_ADAP_G_CAPS ioctl. This option can be combined with −D to uniquely identify a CEC device without having to rely on the device node number.

−E, −−exit−on−fail

Exit this application when the first failure occurs instead of continuing with a possible inconsistent state.

−l, −−list−tests

List all tests and the possible test results. This is used by the −−expect option.

−e, −−expect <test>=<result>

−n, −−expect-with-no-warnings <test>=<result> Fail if the test gave a different result. The −−list−tests option lists all the possible tests and what result values can be used.

This can be used in test scripts to verify that a specific result was returned by the test. One use-case is to verify that an optional feature is actually supported, so an OK result instead of an OK (Not Supported) result is expected.

It can also be used to accept known failures. In that case the test will not fail, but return an OK (Expected Failure) result.

The −−expect-with-no-warnings variant is more strict and will also check that the test produced no warnings.

−v, −−verbose

Turn on verbose reporting.

−−version

Show version information.

−w, −−wall−clock

Show timestamps as wall-clock time. This also turns on verbose reporting.

−T, −−trace

Trace all called ioctls. Useful for debugging.

−h, −−help

Prints the help message.

−W, −−exit−on−warn

Exit this application when the first warning occurs instead of continuing.

−s, −−skip−info

Skip the Driver Info output section.

−C, −−color <when>

Highlight OK/warn/fail/FAIL strings with colors. OK is marked green, warn is marked bold, and fail/FAIL are marked bright red if enabled. <when> can be always, never, or auto (the default).

−N, −−no−warnings

Turn off warning messages.

−r, −−remote <la>

As initiator test the remote logical address <la> or all LAs if no LA was given.

−i, −−interactive

Interactive mode when doing remote tests.

−R, −−reply−threshold <timeout>

Warn if replies take longer than this threshold (default 1000ms).

−t, −−timeout <secs>

Set the standby/resume timeout to the given number of seconds. Default is 60s.

−A, −−test−adapter

Test the CEC adapter API

−F, −−test−fuzzing

Test the remote CEC adapter by randomly creating CEC messages. This runs forever until an error occurs.

−−test−core

Test the core functionality

−−test−audio−rate−control

Test the Audio Rate Control feature

−−test−audio−return−channel−control

Test the Audio Return Channel Control feature

−−test−capability−discovery−and−control

Test the Capability Discovery and Control feature

−−test−deck−control

Test the Deck Control feature

−−test−device−menu−control

Test the Device Menu Control feature

−−test−device−osd−transfer

Test the Device OSD Transfer feature

−−test−dynamic−audio−lipsync

Test the Dynamic Audio Lipsync feature

−−test−osd−display

Test the OSD Display feature

−−test−one−touch−play

Test the One Touch Play feature

−−test−one−touch−record

Test the One Touch Record feature

−−test−power−status

Test the Power Status feature

−−test−remote−control−passthrough

Test the Remote Control Passthrough feature

−−test−routing−control

Test the Routing Control feature

−−test−system−audio−control

Test the System Audio Control feature

−−test−system−information

Test the System Information feature

−−test−timer−programming

Test the Timer Programming feature

−−test−tuner−control

Test the Tuner Control feature

−−test−vendor−specific−commands

Test the Vendor Specific Commands feature

−−test−standby−resume

Test standby and resume functionality. This will activate testing of Standby, Give Device Power Status and One Touch Play.

EXIT STATUS

On success, it returns 0. Otherwise, it will return the error code.

EXAMPLE

We want to test the compliance of a TV when it is interacting with a Playback device. The device node of the CEC adapter which the TV is connected to is /dev/cec1.

The local CEC adapter first needs to be configured as a Playback device, and it must have an appropriate physical address. It is important that the physical address is correct, so as to not confuse the device under test. For example, if the CEC adapter is connected to the first input of the TV, the physical address 1.0.0.0 should generally be used.

cec-ctl -d1 --playback --phys-addr 1.0.0.0

Most CEC adapters will automatically detect the physical address, and for those adapters the --phys-addr option is not needed.

Next, cec-follower also has to be started on the same device:

cec-follower -d1

cec-compliance can now be run towards the TV by supplying the -r option with the logical address 0:

cec-compliance -d1 -r0

BUGS

This manual page is a work in progress.

Bug reports or questions about this utility should be sent to the [email protected] mailinglist.

SEE ALSO

cec-follower(1), cec-ctl(1)


Updated 2024-01-29 - jenkler.se | uex.se